-40%

Fluke Calibration 9144-B-156 Field Dry-Well Metrology Temp Calibrator

$ 3231.36

Availability: 100 in stock
  • Brand: Fluke Calibration
  • All returns accepted: Returns Accepted
  • Return shipping will be paid by: Buyer
  • Item must be returned within: 30 Days
  • Refund will be given as: Money back or replacement (buyer's choice)
  • UPC: 095969420280
  • MPN: 9144-B-156
  • Condition: New

    Description

    Subscribe to Our Newsletter
    Fluke Calibration 9144-B-156 Field Dry-Well Metrology Temperature Calibrator with Model 9144-INSB ("B" Insert), 50 °C to 660 °C
    Brand:
    Fluke Calibration
    Model No:
    9144-B-156
    Ref No:
    3054984
    Our Model No:
    9144B156
    Product Overview
    Features
    9144
    Temperature range at 23°C: 50°C to 660°C (122°F to 1220°F)
    Display accuracy: ±0.35°C at 50°C; ±0.35°C at 420°C; ±0.5°C at 660°C
    Stability: ±0.03°C at 50°C; ±0.04°C at 420°C; ±0.05°C at 660°C
    Axial uniformity at 40 mm (1.6 in): ±0.05°C at 50°C; ±0.35°C at 420°C; ±0.5°C at 660°C
    Radial uniformity: ±0.02°C at 50°C; ±0.05°C at 420°C; ±0.10°C at 660°C
    Lightweight, portable, and fast
    Cool to -25°C in 15 minutes and heat to 660°C in 15 minutes
    Built-in two-channel readout for PRT, RTD, thermocouple, 4-20 mA current
    True reference thermometry with accuracy to ±0.01°C
    On-board automation and documentation
    Metrology performance in accuracy, stability, uniformity, and loading
    9144-INSB
    Six imperial comparison holes
    Hole quantities and sizes: 1 Hole, 3/8 in.; 2 Holes, 1/4 in.; 2 Holes, 3/16 in.; 1 Hole, 1/8 in.
    Removable inserts sized for probes with named diameter
    Use additional inserts to broaden range of hole sizes available
    For use with Model 9144
    Description
    The Fluke Calibration 9144B156 Field Metrology Well Temperature Calibrator with Model 9144-INSB ("B" Insert), 50 °C to 660 °C is designed to be a reliable, stable heat sources that can be used in the field or laboratory. It offers accuracy, portability, and speed for nearly every field calibration application. The instrument has been designed with the field user in mind and is easy to use while maintaining stability, uniformity, and accuracy comparable to some laboratory instruments.
    The Fluke Calibration 9144-B-156 has special, built-in features that make it extremely adaptable. The exclusive Voltage Compensation allows the technician to plug into mains power without degradation to the instrument. The Ambient Temperature Compensation provides a large operating range, with an equally large, guaranteed temperature range. The Gradient Temperature Compensation keeps the axial gradient within specification over the entire temperature range of the 9144-B-156 and over the specified guaranteed operating temperature range. These combined features, along with the rugged design, light weight, and small size make this instrument ideal for field applications.
    The Fluke Calibration 9144-B-156 has a unique Air Flow Design that keeps the probe handle cool, while protecting delicate instruments, as well as the user. The Block Temperature Indicator shows the user when the well temperature is above 50°C, letting the user know when it is safe to remove the insert or move the instrument. The indicator light illuminates when the instrument is energized and the well is above 50°C. If the instrument is removed from mains power, the indicator light flashes until the well has cooled to less than 50°C.
    The Fluke Calibration 9144-B-156 controller uses a PRT sensor and thermoelectric modules or heaters to achieve stable, uniform temperatures throughout the block.
    The LCD display continuously shows many useful operating parameters, including the block temperature, the current set-point, block stability, and heating and cooling status. For the Process version, the reference temperature and secondary input type (UUT) readings are displayed. The display can be set to show the information in one of eight different languages: English, Japanese, Chinese, German, Spanish, French, Russian, and Italian.
    The Fluke Calibration 9144-B-156's rugged design and special features make it ideal for the field or the laboratory. With proper use, this instrument provides continued accurate calibration of temperature sensors and devices. Before use, the user should be familiar with the calibrator's warnings, cautions, and operating procedures as they are described in the User Manual.
    Included Components
    1 - "B" Insert (9144-INSB)
    1 - Power Cord
    1 - RS-232 Cable
    1 - Report of Calibration and Calibration Label
    1 - Insert Removal Tool
    1 - Interface-it Software/Manual (9930)
    1 - Technical Manual CD
    1 - User Manual
    Terms & Conditions
    Please note estimated delivery time above. Contact us for details or if you have a delivery requirement. We ask for your patience while striving to ensure your shipment arrives quickly and accurately.
    Domestic Shipping
    FREE Standard Shipping on items OVER and less than 30lbs to continental U.S. Add for AK, HI, or PR. Please contact us for shipping rates to any overseas US territories including: Northern Mariana Islands, Guam, Puerto Rico, U.S. Virgin Islands and American Samoa.
    PO Boxes/APOs require USPS shipping and may therefore experience longer lead times
    6.25% Sales Tax for shipping to MA
    International Shipping
    Due to international voltage requirements, please ask us prior to purchasing to confirm your product will operate correctly in your country.
    Please contact us for shipping rates to any overseas U.S. territories.
    International customers are responsible for all shipping charges, including any duties or taxes.